4.4 Description of the units
4 Function description
System status
Funktion_Display_OSSD
Status of the OSSD
Funktion_Display_Betriebszustand_P_Variante
Operating state
Funktion_D isplay_Eingabefeld
Status Description
SYSTEM OK The PSENvip is performing the specified operating mode
without error, see table: "Operating status"
TEST The PSENvip is performing calibration and internal tests.
STANDBY The PSENvip is deactivated when the press is in setup
mode.
ERROR An error has occurred (HOLD, STOP, FATAL). See
Chapter 9, "Diagnostics and Troubleshooting"
Status Description
OSSD ON The output signal switching devices OSSD1 and OSSD2
are in the ON state.
The protected field is clear.
OSSD OFF The output signal switching devices OSSD1 and OSSD2
are in the OFF state.
The protected field is interrupted. Or the PSENvip is not in
the status: SYSTEM OK or NORMAL OPERATION
State Description
NORMAL OP-
ERATION
One of the protected field modes is activated.
See Chapter 8, "Operation"
SETUP This is the operating mode in which you enter the overrun.
See Chapter 7, "Commissioning"
TOOL CHANGE This is the operating mode in which you track the adjust-
ment line to the tip of the tool during a tool change.
See Chapter 7, "Commissioning"
ADJUSTMENT This is the operating mode in which you set up the trans-
mitter and receiver mechanically so that they are calibrated
with each other.
See Chapter 7, "Commissioning"
DIAGNOSTICS System data and error codes are displayed in this menu.
Pilz technical support can use these to locate errors.
See Chapter 9, "Diagnostics and Troubleshooting"
MENU On pressing the <MODE> key, you can choose between
the following
options:
- TOOL CHANGE: Adjustment during tool change
- ADJUSTMENT: Adjustment during initial commissioning
- DIAGNOSTICS: Display error codes