Pilz PSENvip RL D P Manual de usuario Pagina 32

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 139
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 31
4.1 Overview
4 Function description
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-4
Fig. 4-3: Definitions
Key:
1: Light beam bundle
2: Illuminated target area
3: Protected field
4: Detection zone
Funktion_Schutzfeld_allgemein
The shape and size of the protected field depend on the bending func-
tion and the machine-dependent overrun. A reduced protected field is
possible for box bending and/or back gauge mode (for the size of the
protected field please see "Protected field" section and the chapter en-
titled "Technical Details").
If an object encroaches into the detection zone, both output signal
switching devices (OSSD1 and OSSD2) on the PSENvip will switch to
the OFF-state. The safety system will use these signals to initiate stop-
ping of the press stroke.
1
2
3
4
Vista de pagina 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 138 139

Comentarios a estos manuales

Sin comentarios