Setting Parameters
4-16 PROFIBUS-DP-Slave Operating Manual
Example 4 :
100 words input and output
Configuration byte: C0
Length byte input (64 words): FF
Length byte output (64 words): FF
Configuration byte: C0
Length byte input (36 words): E3
Length byte output (36 words): E3
Diagnostics: 3 words of internal diagnostic data
1 word of device-related diagnostic data
50 bytes of user-specific diagnostic data
Data word Contents Description
DW 0000 - DW 0099 ... Input data
DW 0128 - DW 0227 ... Output data
DW 0258 KH 2500 ID-number
DW 0259 KH 0052 Device-related diagnostics
DW 0384 KH FFC0 Configuration data
DW 0385 KH C0FF
DW 0386 KH E3E3
DW 0783 KF 58 max_diag_len [Byte]
DW 0795 KH F5 Pre-assigned
DW 0800 KF 1 Slave address [0-126]
DW 0801 KF 0 Transmission sequence
DW 0810 KF 100 Length of input data in words
DW 0811 KF 100 Length of output data in words
DW 0812 KF 29 Length of diagnostic data in words
DW 0813 KF 6 Amount of configuration data in bytes
DW 0814 KF 0 Pre-assigned
DW 0815 KF 0 Pre-assigned
Comentarios a estos manuales