Setting Parameters
4-12 PROFIBUS-DP-Slave Operating Manual
• Enter the length of the input data in data word DW 0810 and the length of
the output data in data word DW 0811.
• Always enter “0” in data words DW 0814 and DW 0815.
Data block configuration:
NOTICE
Only edit data words and output data that are shaded grey.
Data words 256, 257, 512 ... 782, 784 ... 794, 796 ... 799, 802 ... 809 and
816 ... 1023 cannot be amended!
Data word Type Contents
DW 0000...DW 0127 Input data Master --> PSS
DW 0128...DW 0255 Output data PSS --> Master
DW 0256 Reserved for internal diagnostic data
DW 0257 Reserved for internal diagnostic data
DW 0258 KH ID number: 2500 hex
DW 0259 KH Device-specific diagnostic data [Byte]
1 Byte Header (DR 0259)
+ 1 Byte Pilz diagnostics (DL 0259)
+ x Byte user diagnostics (DR 0260ff)
DW 0260...DW 0383 KH User-specific diagnostic data
DW 0384...DW 0511 KH Configuration data
DW 0512...DW 0782 Reserved
DW 0783 KF max_diag_len [Byte] (>2 x DW 0812)
DW 0784...DW 0794 Reserved
DW 0795 KH Only F5 hex is permitted
DW 0796...DW 0799 Reserved
DW 0800 KF Slave address 0 ... 126
Equals coding switch on the module
DW 0801 KF Transmission sequence of Bytes 0 or 1
DW 0802...DW 0809 Reserved
DW 0810 KF Length of input data 0 - 122 [Words]
DW 0811 KF Length of output data 0 - 122 [Words]
DW 0812 KF Length of diagnostic data 4 - 35 [Words]
3 words internal diagnostics (DW 0256 ...
DW 0258)
x words device-specific diagnostics
(= DW 0259 / 2)