PROFIBUS-DP-Slave Operating Manual 4-9
Setting Parameters
ID-Byte:
Bit No. 7 6 5 43210
xx00xxxx
Length of manufacturer-specific data
ID-code
00 = Reserved
01 = 1 length byte for PSS output data follows
10 = 1 length byte for PSS input data follows
11 = 1 length byte for PSS input data and one length byte for
PSS output data follow
INFORMATION
Manufacturer-specific data is not pre-assigned by Pilz. Users may enter
their own data - please refer to the standard.
If no data is to be entered, enter the value 0 in Bits 0 ... 3 .
Length-Byte:
Bit No. 7 6 5 43210
x1xxxxxx
Length of data: 000000 ... 111111 corresponds to
1 ... 64 words
Data structure: 1: Word, 0: Byte
We recommend you set Bit 6 = 1 (Word)
Consistency: 0: for one word, 1: for the whole data length
INFORMATION
The amount of configuration data must be entered in Bytes in DW 0813.