6.2 Connections
6 Wiring
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
6-4
6.2Connections6200Connections6-
6.2.1 Receiver
Receiver6-Funktion_Geraete_Empfaenger_Stecker
The top of the receiver has two 8-pin M12 connectors.
Verdrahtung_Anschluss_Empfaenger
Fig. 6-2: M12 connector on the receiver
The receiver is connected via two 8-pin cables.
Fig. 6-3: Receiver's pin assignment
The cable ends of the Pilz ready-made cable are colour-coded. Please
refer to the tables below for the coding details.
Verdrahtung_Anschluss_Empfaenger_Basis
Pin assignment of M12 connector X1 on the receiver
PIn No. Designation Description Colour
1 Overrun measurement 1 Output, result of overrun measurement White
Tool class PSENvip -> PLC Bit 1
*)
Output, sends tool class Bit 1 to safety system
2 24 VDC Input, 24 VDC supply voltage Brown
3 Protected field mode 1 Input, setting of protected field modes Green
Tool class PLC -> PSENvip Bit 1
*)
Input, safety system reflects tool class Bit 1
4 Protected field mode 2 Input, setting of protected field modes Yellow
Tool class PLC -> PSENvip Bit 2
*)
Input, safety system reflects tool class Bit 2
5 OSSD1 Output, OSSD1 Grey
6 Activate *) Output: Start communication with safety system Pink
7 0 V Input, 0 V supply voltage Blue
Comentarios a estos manuales