7-17
7.3 Adjustment during tool change
7 Commissioning
Tool class 2
The contour of these tools is fully detected by the PSENvip.
The front (V2) and rear (H2) bending lines are within the protected
field.
The front segments of the protected field are less than 15 mm away
from the front bending line.
These tools are not safeguarded in compliance with the standards.
Example:
Fig. 7-15: Example for tool class 2
Tool class 3
The contour of these tools is not fully detected by the PSENvip.
The front (V3) and/or rear (H3) bending lines are within the protected
field.
These tools are not safeguarded in compliance with the standards.
Example:
Fig. 7-16: Example for tool class 3
> 25 mm
<15 mm
HV
HV