4.5 Protected field modes
4 Function Description
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-26
4.5Protected field modes4500Protected field modes4-Funktion_Schutzfeldmodus
Four protected field modes are available for adapting to different bend-
ing functions:
Full protected field: Standard press stroke
Reduced protected field:
Box bending press stroke
Back gauge press stroke
Box bending with back gauge press stroke
Funktion_Schutzfeldmodus_Werkzeugklasse
Use of the protected field modes depends on the tool class. Not all pro-
tected field modes can be selected with tool class 2 and 3.
4.5.1 Standard protected field mode
Standard protected field mode4-Funktion_Schutzfeldmodus_Standard
The full protected field is available with standard protected field mode.
This protected field mode is applied for flat workpieces.
Fig. 4-12: Standard protected field mode
Protected field mode Tool class
123
Standard
Full protected field
Yes Yes Yes
Box bending
Front segments blanked
Yes Yes No
Back gauge
Rear segments blanked
Yes No No