Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
4-23
4.4 Description of the units
4 Function Description
Key to inputs and outputs:
Funktion_Kommunikation_Ablauf
Communication sequence:
Terminal Input/output Normal mode Communication with safety sys-
tem
Notes
X1, 6 Output No function Activate The PSENvip starts com-
munication.
X2, 6 Output No function Acknowledge PSENvip -> PLC The PSENvip confirms
the validity of the tool
class registered on the
safety system.
X1, 1 Output Overrun measure-
ment 1
Tool class PSENvip -> PLC Bit 1 The PSENvip sends Bit 1
of the detected tool class
to the safety system.
X2, 1 Output Overrun measure-
ment 2
Tool class PSENvip -> PLC Bit 2 The PSENvip sends Bit 2
of the detected tool class
to the safety system.
X2, 2 Input Power Off PLC Ready The safety system is
ready for communication.
X1, 3 Input Protected field
mode 1
Tool class PLC -> PSENvip Bit 1 The safety system re-
flects Bit 1 of the tool
class.
X1, 4 Input Protected field
mode 2
Tool class PLC -> PSENvip Bit 2 The safety system re-
flects Bit 2 of the tool
class.
PLC Ready
1
0
1
0
1
0
1
0
1
0
Activate
Acknowledge PSENvip -> PLC
1
0
Tool class PSENvip -> PLC Bit 1
1
0
Tool class PSENvip -> PLC Bit 2
Tool class PLC -> PSENvip Bit 1
Tool class PLC -> PSENvip Bit 2
12345 6 7
max. 600 ms
max.
200 ms
max.
200 ms
max.
200 ms
Comentarios a estos manuales