PNOZs4
OperatingManualPNOZs4
21396EN13
6
}
Aconnectorcanbeusedtoconnect1PNOZsigmacontactexpansionmodule
}
Operatingmodescanbesetviarotaryswitch
}
LEDindicatorfor:
– Supplyvoltage
– Inputstatus,channel1
– Inputstatus,channel2
– Switchstatusofthesafetycontacts
– Startcircuit
– Errors
}
Pluginconnectionterminals(eitherspringloadedterminalorscrewterminal)
Safetyfeatures
Therelaymeetsthefollowingsafetyrequirements:
}
Thecircuitisredundantwithbuiltinselfmonitoring.
}
Thesafetyfunctionremainseffectiveinthecaseofacomponentfailure.
}
Thecorrectopeningandclosingofthesafetyfunctionrelaysistestedautomaticallyin
eachonoffcycle.
}
Theunithasanelectronicfuse.
Blockdiagram/terminalconfiguration
InputInput
A1 A2 S21 S22
=
Power
Reset/
Start
S34
S11 S12
=
Y32
(~)
K1
K2
13
23 33
24 34
14
41
42
Interface
expansion
unit
( )
*
*
Fig.:RotarycamarrangementmonitoringFrontviewwithcover,right:Frontviewwithoutcover
Greyhighlightedarea:AppliesonlywithU
B
=48–240VAC/DC
*Insulationbetweenthenonmarkedareaandtherelaycontacts:Basicinsulation(over
voltagecategoryIII),Protectiveseparation(overvoltagecategoryII)