4-35
4.7 System cycle
4 Function Description
4
5
6
State Bottom dead centre
Foot switch 1
System-Init 0
OSSD 0
Creep speed mode SG 1
Protected field Interrupted
State Upward movement
Rapid traverse
Foot switch 1
System-Init 1
OSSD 1 or 0
Creep speed mode SG 0
Protected field Free or interrupted
State Press is at top dead centre
Foot switch 0
System-Init 1
OSSD 1
Creep speed mode SG 0
Protected field Free
v = 0
v > 10 mm/s
v £ 10 mm/s
v = 0
v = 0
v > 10 mm/s
v £ 10 mm/s
v = 0
v = 0
v > 10 mm/s
v £ 10 mm/s
v = 0