Pilz PSENvip RL D P Manual de usuario Pagina 43

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 148
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 42
4.4 Description of the units
4 Function Description
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-16
4.4.3.2 Outputs
Outputs4-Funktion_Geraete_Empfaenger_Ausgang_OS SD
OSSD1/OSSD2 in accordance with EN 61496-1, type 4
Two safe outputs that signal the status of the protected field:
OSSD = 1: Protected field clear
OSSD = 0: Protected field broken
Funktion_Geraete_Empfaenger_Ausgang_OS SD_Zusatz_Basis
Funktion_Geraete_Empfaenger_Ausgang_Ausgangstest
Output test
Outputs that are switched on are checked via regular off tests.
Test pulses for outputs that are switched on: see Technical Details
Outputs that are switched on are switched off for the duration of the
test pulse.
The load must not switch off because of the test.
Outputs that are switched off are checked via regular on tests.
Test pulses for outputs that are switched off: see Technical Details
Outputs that are switched off are switched on for the duration of the
test pulse.
The load must not switch on because of the test.
Testing for shorts
A test is regularly carried out to check for shorts between the outputs.
Fig. 4-7: Test pulses
Key:
t
1
: Pulse length of on test (40 μs)
t
2
: Repetition length of on test (100 μs ... 3 ms)
t
3
: Cycle time of on test (30 μs ... 5 min)
INFORMATION
The programmable safety system uses the signals to shut down
the press stroke at closing speeds >10 mm/s.
1
t
2
t
1
t
1
t
3
t
1
t
t
2
t
1
U