Servicelifegraph
Theservicelifegraphsindicatethenumberofcyclesfromwhichfailuresduetowearmust
beexpected.Thewearismainlycausedbytheelectricalload;themechanicalloadisnegli
gible.
Example
}
Inductiveload:0,2A
}
Utilisationcategory:AC15
}
Contactservicelife:2,000,000cycles
Providedtheapplicationrequiresfewerthan2,000,000cycles,thePFHvalue(seetech
nicaldetails)canbeusedinthecalculation.
Toincreasetheservicelife,sufficientsparksuppressionmustbeprovidedonalloutput
contacts.Withcapacitiveloads,anypowersurgesthatoccurmustbenoted.Withcontact
ors,usefreewheeldiodesforsparksuppression.
Orderreference
Type Features Terminals Orderno.
PNOZc1 24VDC Withspringloadedterminals 710001
ECDeclarationofConformity
Thisproduct/theseproductsmeettherequirementsofthedirective2006/42/ECforma
chineryoftheEuropeanParliamentandoftheCouncil.ThecompleteECDeclarationof
ConformityisavailableontheInternetatwww.pilz.com/downloads.
Representative:NorbertFröhlich,PilzGmbH&Co.KG,FelixWankelStr.2,73760Ost
fildern,Germany