Technical Details
Operating Manual PNOZ m1p (ETH)
20878-EN-12
33
Environmental data 773100 773103 773104 773105
Climatic suitability
In accordance
with the standard
EN 60068-2-30, EN
60068-2-78
EN 60068-2-30, EN
60068-2-78
EN 60068-2-30, EN
60068-2-78
EN 60068-2-30, EN
60068-2-78
Humidity 93 % r. h. at 40 °C 93 % r. h. at 40 °C 93 % r. h. at 40 °C 93 % r. h. at 40 °C
Condensation Not permitted Not permitted Short-term (only
with protective ex-
tra low voltage)
Short-term (only
with protective ex-
tra low voltage)
EMC EN 61131-2 EN 61131-2 EN 61131-2 EN 61131-2
Vibration
In accordance
with the standard
EN 60068-2-6 EN 60068-2-6 EN 60068-2-6 EN 60068-2-6
Frequency 10,0 - 150,0 Hz 10,0 - 150,0 Hz 5,0 - 500,0 Hz 5,0 - 500,0 Hz
Max. acceleration 1g 1g 1g 1g
Broadband noise
In accordance
with the standard
– – EN 60068-2-64 EN 60068-2-64
Frequency – – 5 - 500 Hz 5 - 500 Hz
Max. acceleration – – 19 m/s² rms 19 m/s² rms
Corrosive gas check
SO2: concentra-
tion 10 ppm, du-
ration 10 days,
passive
– – DIN V 40046-36 DIN V 40046-36
H2S: concentra-
tion 1 ppm, dura-
tion 10 days, pas-
sive
– – DIN V 40046-37 DIN V 40046-37
Shock stress
In accordance
with the standard
EN 60068-2-27 EN 60068-2-27 EN 60068-2-27 EN 60068-2-27
Acceleration 15g 15g 15g 15g
Duration 11 ms 11 ms 11 ms 11 ms
Max. operating
height above sea
level
2000 m 2000 m 2000 m 2000 m
Airgap creepage
In accordance
with the standard
EN 61131-2 EN 61131-2 EN 61131-2 EN 61131-2
Overvoltage cate-
gory
III III III III
Pollution degree 2 2 2 2
Rated insulation volt-
age
250 V 250 V 250 V 250 V
Rated impulse with-
stand voltage
6,00 kV 6,00 kV 6,00 kV 6,00 kV