Pilz PNOZ m1p base unit Manual de usuario

Busca en linea o descarga Manual de usuario para Sensores Pilz PNOZ m1p base unit. Pilz PNOZ m1p base unit User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - PNOZ m1p (ETH)

PNOZ m1p (ETH)Operating Manual-20878-EN-12Configurable Control System PNOZmulti

Pagina 2 - Preface

SafetyOperating Manual PNOZ m1p (ETH) 20878-EN-1210SafetyIntended useThe configurable control system PNOZmulti is used for the safety-related interrup

Pagina 3

SafetyOperating Manual PNOZ m1p (ETH) 20878-EN-1211Warranty and liabilityAll claims to warranty and liability will be rendered invalid if} The produc

Pagina 4

Function descriptionOperating Manual PNOZ m1p (ETH) 20878-EN-1212Function descriptionIntegrated protection mechanismsThe relay conforms to the followi

Pagina 5 - Introduction

Function descriptionOperating Manual PNOZ m1p (ETH) 20878-EN-1213DiagnosticsThe status and error messages displayed by the LEDs are saved in an error

Pagina 6 - Overview

InstallationOperating Manual PNOZ m1p (ETH) 20878-EN-1214InstallationGeneral installation guidelines} The control system should be installed in a con

Pagina 7 - Front view

InstallationOperating Manual PNOZ m1p (ETH) 20878-EN-1215DimensionsInstall base unit without expansion module} The te

Pagina 8 - 

InstallationOperating Manual PNOZ m1p (ETH) 20878-EN-1216Expansion module 1 ... 8JumpersTerminatorFieldbus moduleBase unitExpansion module 1 ... 4Powe

Pagina 9

CommissioningOperating Manual PNOZ m1p (ETH) 20878-EN-1217CommissioningWiringThe wiring is defined in the circuit diagram in the Configurator. There y

Pagina 10 - Use of qualified personnel

CommissioningOperating Manual PNOZ m1p (ETH) 20878-EN-1218Ethernet interfaces (only PNOZ m1p ETH)RJ45 interfaces ("Ethernet")Two free switch

Pagina 11 - 20878-EN-12

CommissioningOperating Manual PNOZ m1p (ETH) 20878-EN-1219RJ45 connection cableRJ45 connector8-pinCAUTION!

Pagina 12 - Function description

PrefaceThis document is a translation of the original document.All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may

Pagina 13

CommissioningOperating Manual PNOZ m1p (ETH) 20878-EN-1220Process data exchangeThe RJ45 interfaces on the internal autosensing switch enable process d

Pagina 14 - Installation

CommissioningOperating Manual PNOZ m1p (ETH) 20878-EN-1221Commissioning the PNOZmulti control system for the first timeProcedure:} Wire the inputs an

Pagina 15 - 

CommissioningOperating Manual PNOZ m1p (ETH) 20878-EN-1222Download modified project to the control system PNOZmultiLoad modified project from chip car

Pagina 16

CommissioningOperating Manual PNOZ m1p (ETH) 20878-EN-1223Input circuit Single-channel Dual-channelE-STOPwithout detection of shorts across contacts

Pagina 17 - Commissioning

CommissioningOperating Manual PNOZ m1p (ETH) 20878-EN-1224Redundant output Single output Connection examples f

Pagina 18 - 

CommissioningOperating Manual PNOZ m1p (ETH) 20878-EN-1225Connection exampleDual-channel E-STOP and safety gate wiring, monitored start (I17), feedbac

Pagina 19 - RJ45 connection cable

OperationOperating Manual PNOZ m1p (ETH) 20878-EN-1226OperationWhen the supply voltage is switched on, the PNOZmulti safety system copies the configu-

Pagina 20 - Preparing for operation

OperationOperating Manual PNOZ m1p (ETH) 20878-EN-1227Internal error on the base unitInternal error on the base unitInternal error on the expansion mo

Pagina 21

OperationOperating Manual PNOZ m1p (ETH) 20878-EN-1228Display elements for the Ethernet connection (only PNOZ m1p ETH)The operating and fault states o

Pagina 22 - Connection

Technical DetailsOperating Manual PNOZ m1p (ETH) 20878-EN-1229Technical DetailsGeneral 773100 773103 773104 773105Approvals BG, CCC, CE, GOST, KCC, KO

Pagina 23

ContentOperating Manual PNOZ m1p (ETH) 20878-EN-123Section 1 Introduction 51.1 Validity of documentation 51.2 Retaining the documentation 51.3 Definit

Pagina 24

Technical DetailsOperating Manual PNOZ m1p (ETH) 20878-EN-1230Test pulse outputs 773100 773103 773104 773105Number of test pulse outputs4 4 4 4Voltage

Pagina 25 - Connection example

Technical DetailsOperating Manual PNOZ m1p (ETH) 20878-EN-1231Relay outputs 773100 773103 773104 773105Utilisation categoryIn accordance with the stan

Pagina 26 - Operation

Technical DetailsOperating Manual PNOZ m1p (ETH) 20878-EN-1232Relay outputs 773100 773103 773104 773105Circuit breaker, 24V AC/DC, char-acteristic B/C

Pagina 27

Technical DetailsOperating Manual PNOZ m1p (ETH) 20878-EN-1233Environmental data 773100 773103 773104 773105Climatic suitabilityIn accordance with the

Pagina 28

Technical DetailsOperating Manual PNOZ m1p (ETH) 20878-EN-1234Environmental data 773100 773103 773104 773105Protection typeIn accordance with the stan

Pagina 29 - Technical Details

Technical DetailsOperating Manual PNOZ m1p (ETH) 20878-EN-1235Mechanical data 773100 773103 773104 773105Cross section of ex-ternal conductors with sc

Pagina 30

Technical DetailsOperating Manual PNOZ m1p (ETH) 20878-EN-1236Safety characteristic dataUnit Operating modeEN ISO 13849-1: 2006PLEN ISO 13849-1: 2006C

Pagina 31

Supplementary dataOperating Manual PNOZ m1p (ETH) 20878-EN-1237Supplementary dataMaximum capacitive load C (μF) with load current I (mA) at the semico

Pagina 32

Supplementary dataOperating Manual PNOZ m1p (ETH) 20878-EN-1238Example} Inductive load: 0,2 A} Utilisation category: AC15} Contact service life: 1,

Pagina 33

Order referenceOperating Manual PNOZ m1p (ETH) 20878-EN-1239Order referenceOrder reference Product Type Features Order no.PNOZ m1p Base unit 773 1

Pagina 34

ContentOperating Manual PNOZ m1p (ETH) 20878-EN-1246.3.2.2 Load project via integrated interface 216.3.3 Download modified project to the control syst

Pagina 35

...Sachnummer Printed in Germany © Pilz GmbH & Co. KG, 2011+49 711 [email protected] GmbH & Co. KGFelix-Wankel-Straße 27

Pagina 36 - Safety characteristic data

IntroductionOperating Manual PNOZ m1p (ETH) 20878-EN-125IntroductionValidity of documentationThis documentation is valid for the product m1p. It is va

Pagina 37 - Supplementary data

OverviewOperating Manual PNOZ m1p (ETH) 20878-EN-126OverviewRange} Base unit m1p} Terminator} Documentation on data mediumUnit featuresUsing the pro

Pagina 38

OverviewOperating Manual PNOZ m1p (ETH) 20878-EN-127} Test pulse outputs used to monitor shorts across the inputs} Monitoring of shorts between the

Pagina 39 - Order reference

OverviewOperating Manual PNOZ m1p (ETH) 20878-EN-128PNOZ m1p ETHLegend} CHIP card:– Interface chip card

Pagina 40 - Technical support

OverviewOperating Manual PNOZ m1p (ETH) 20878-EN-129} LEDs:– PWR– RUN– DIAG– FAULT– I FAULT– O FAULT