7-1
7.1 Messages
7 Operation
77000OperationOperation7-7.1Messages7100Messages7-
When the supply voltage is switched on, the PNOZmulti safety system
copies the configuration from the chip card.
The LEDs "POWER","DIAG", "FAULT", "IFAULT" and "OFAULT" light up
on the base unit.
The PNOZmulti safety system is ready for operation when the "POWER"
and "RUN" LEDs on the base unit and the "READY" LED on the PNOZ
ms4p are lit continuously.
7.2Display elements7200Display elements7-
Key:
7.2.1 Display elements for unit diagnostics
Display elements for unit diagnostics7-
LED on
LED flashes
LED off
LED LED status Key
POWER Supply voltage is present
FAULT External fault leading to a safe condition; the fault is at the incremental encoder in-
puts whose LEDs are flashing, e.g. short across the contacts
Internal fault leading to safe condition
SHAFT Input device or wiring fault
Axis is in the normal range (no standstill, no overspeed)
Axis is signalling standstill
Axis is signalling overspeed
X12 Incremental encoder on terminal X12 is connected correctly