Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
6-9
6.2 Preparing for operation
6 Commissioning
6.2.4.3 Connection of an incremental encoder and proximity switch on an axis
Connection of an incremental encoder and proximity switch on an axis6-Drehzahlwaechter_Bsp3_BA
Description
` 1 proximity switch, pnp-switching
` 1 incremental encoder
` Incremental encoder and proximity switch on one axis
Fig. 6-10: Connection of an incremental encoder and proximity
switch, pnp-switching, on an axis
I10
I11
I20
I21
24V
24V
24V
0V
0V
0V
X22X12
+
-
Incremental encoder Drive
...
PNOZ msi1p ... msi4p ...
24 V DC
0 V
Speed monitor
pnp