Commissioning
Operating Manual PNOZ m ES EtherCAT
1003057-EN-01
13
Interface assignment
RJ45 socket
8-pin PIN Standard
1 TD+ (Transmit+)
2 TD- (Transmit-)
3 RD+ (Receive+)
4 n.c.
5 n.c.
6 RD- (Receive-)
7 n.c.
8 n.c.
n.c.: Not connected
Download modified project to the PNOZmulti safety system
As soon as an additional expansion module has been connected to the system, the project
must be amended using the PNOZmulti Configurator. Proceed as described in the operat-
ing instructions for the base unit.
CAUTION!
For the commissioning and after every program change, you must check
whether the safety devices are functioning correctly.
Preparing for operation
} Install Device Description File
Install the Device Description File in your configuration software. You can only then use
the PNOZ m ES EtherCAT.
} Connect the supply voltage to the base unit:
Terminals 24 V and A1 (+): + 24 VDC
Terminals 0 V and A2 (-) : 0 V
6.3
6.4
6.5