Commissioning
OperatingManualPNOZmB0
1002660EN03
21
Singleoutputwithadvancedfault
detection*
Connectionexamplesforsemiconductoroutputs
*Twoloadsmaybeconnectedtoeachsafetyoutputwithadvancedfaultdetection,evenon
applicationsinaccordancewithENIEC62061,SILCL3.Prerequisite:Feedbackloopis
connected,shortsacrosscontactsandexternalpowersourcesareexcluded(e.g.through
separatemulticorecables).Pleasenotethat,intheeventofanerrorinthefeedbackloop,
thesafetysystemswitchestoasafeconditionandshutsdownalltheoutputs.
Feedbackloop Redundantoutput
Contactsfromexternalcontactors
K1
L+
L-
K2
O0 (O2)
O1 (O3)
IM0
L-
Connectionexamplesforfeedbackloop
6.4 Functiontestduringcommissioning
CAUTION!
Itisessentialtocheckthatthesafetydevicesoperatecorrectly
– afterthechipcardhasbeenexchanged
– afteraprojecthasbeendownloaded
– whentheprojecthasbeendeletedfromthebaseunit'smemory("Re
setProject"menu)
6.5 Usingthechipcard
NOTICE
Thechipcardcontactisonlyguaranteedifthecontactsurfaceiscleanand
undamaged.Forthisreasonpleaseprotectthechipcard'scontactsurface
from
– Contamination
– Contact
– Mechanicalimpact,suchasscratches.